$99 / Case
Econo-Pack 150/Box 10 box Case
( Case = 1500 Gloves )
|
UniSeal® PLATINUM Nitrile ( 4 mil 9"cuff )
Chemotherapy Gloves
Medical Grade - (Non Latex) - Powder-Free
PLATINUM Nitrile Gloves Features
- 4 mil thickness 9" Beaded Cuff
- Thin Wall PLATINUM Nitrile Glove technology for extra strength and durability
- Micro-Textured Finger tips for superior grip
- Latex-Free & Powder Free
- Medical Grade
- Tested for use with 10 Chemotherapy Drugs
- Soft Comfortable fit reduces hand fatigue
- Comfortable to wear for extended periods
- Bar-coded boxes and cartons
- Dated Lot Codes for quality assurance and traceability
- Safety Sealed Packaging
- For Single Use Only
- Econo-Pack 150 Gloves/Box, 10 Boxes/Case
( Case = 1500 Gloves )
|
| |
|
| UniSeal® PLATINUM Nitrile Chemotherapy Gloves are manufactured in accordance with ASTM D 6978 Standard Practice for Assessment of Resistance of Medical Gloves to Permeation of Chemotherapy Drugs. |
| |
|
|
|
CHEMOTHERAPY DRUGS |
BREAKTHROUGH DETECTION TIME (Minutes) |
| Casplatin (1,000 ppm) |
No breakthrough was detected up to 240 minutes |
| Cyclophosphamide (20,000 ppm) |
No breakthrough was detected up to 240 minutes |
| Dacarbazine (10,000 ppm) |
No breakthrough was detected up to 240 minutes |
| Doxorubicin Hydrochloride (2,000 ppm) |
No breakthrough was detected up to 240 minutes |
| Etoposide (20,000 ppm) |
No breakthrough was detected up to 240 minutes |
| Fluorouracil (50,000 ppm) |
No breakthrough was detected up to 240 minutes |
| Paclitaxel (6,000 ppm) |
No breakthrough was detected up to 240 minutes |
| Carmustine (3,300 ppm) |
No breakthrough was detected up to 58 minutes |
| Thio-Tapa (10,000 ppm) |
No breakthrough was detected up to 146 minutes |
Medical Grade Chemotherapy Gloves
UniSeal(R) PLATINUM Nitrile Chemotherapy Gloves are manufactured in accordance with FDA specifications. These disposable nitrile Chemotherapy gloves are regulated by the Food and Drug Administration (FDA). FDA makes sure that manufacturers of these devices meet performance criteria such as leak resistance, tear resistance, etc.
The protection offered by a disposable nitrile Chemotherapy glove, referred to as its barrier effectiveness, is the ability of the exam glove to withstand viral penetration. Gloves that pass Viral Penetration Tests (ASTM 6319-00a) provide an effective barrier against bloodborne pathogens, as mandated by the Food and Drug Administration (FDA), the Centers for Disease Control and Prevention (CDC), the Occupational Safety and Health Administration (OSHA) and the National Institute for Occupational Safety and Health (NIOSH).
Featuring UniSeal® Gloves Exclusively
Only the Best..... |
|
Protection from the risk of contact with infectious, biological, and hazardous materials.
Disposable Medical and All-Purpose - Nitrile Gloves - Latex Gloves - Vinyl Gloves - High Risk Gloves
|